DE660 GC (50 Hz) Generator Set

Diesel Generator Sets
Diesel Generator Sets (172)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Generator Set Specifications

Minimum Rating
660 kVA
Maximum Rating
660 kVA
Emissions/Fuel Strategy
Non Regulated
Voltage
380 to 415 Volts
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model
C15 In-line 6, 4-cycle diesel
Bore
5.4in
Stroke
6.8in
Displacement
928in³
Compression Ratio
16.1:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
EUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
131in
Width - Maximum
60.6in
Height - Maximum
86.1in
Dry Weight - Genset (maximum)
8364lb

Standard/Optional Features

Standard Equipment:

  • Engine
    • Cat® C15 Inline 6 cylinder, 4 stroke diesel
  • Air Inlet
    • Air cleaner
  • Control Panels
    • GCCP 1.1
  • Governor
    • Mechanical governor
  • Cooling
    • Package mounted radiator
  • Alternator
    • A Frame standard alternator
  • Fuel Storage
    • Single wall 8 hour fuel tank
  • Cooling System
    • Radiator and cooling fan with guards
    • Fan drive, battery charging alternator drive
  • Fuel
    • Fuel priming pump
    • Primary fuel filter with integral water separator
    • Secondary fuel filters
  • Electrical Options
    • 3 Pole Circuit breaker
    • Neutral earth link
    • 24 Volt battery with rack and cables
  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Generator
    • Matched to the performance and output characteristics of Cat engines
    • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • IP23 Protection
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators
    • Lifting provision and drag points
  • General
    • Engine and alternator pre paint, Caterpillar yellow
    • Engine and alternator pre paint, Caterpillar yellow
  • Power Termination
    • Busbar
  • Generator And Attachments
    • Power center, IP22
    • Segregated low voltage (AC/DC) wiring panel
    • Optional LC Frame generator - IP23 Protection
    • Integrated voltage regulator (IVR)
    • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Mounting
    • Rubber vibration isolators
  • Governing System
    • Cat electronic governor (ADEM A4).
  • Lube System
    • Oil cooler
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Optional Equipment:

  • Control Panel
    • PLG 4G/3G/Ethernet
    • Annunciator
    • Emergency E-Stop
  • Exhaust
    • Industrial, residential, critical mufflers
  • Enclosure
    • Cat GC enclosure
  • Generator
    • Oversize and premium generators
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Anti-condensation heater
  • Electrical Options
    • 4 Pole Circuit breaker
    • Auxiliary contacts
    • Padlockable circuit breaker
    • Battery charger
    • Wet battery
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • Alternator
    • Space heater
    • AVR
  • Generator And Attachments
    • Oversize A Frame generator
    • LC frame generator
    • LC frame CIP generator
    • Ingress protection
    • CIP A Frame generator
    • Permanent magnet excitation (PMG) generator
    • Oversize LC frame generator
    • Space heaters
  • Starting/charging
    • Oversize batteries
    • Charging alternator
    • Jacket water heater
    • Battery chargers
    • Heavy duty starting system
    • 24 Volt battery with rack and cables
  • Air Inlet System
    • Single stage air filter
    • Dual element air filter
  • Certifications
    • EU Certificate of Conformance (CE)
    • EAC Certification
  • General
    • The following options are based on regional and product configuration:
    • Sound attenuated, weather protective or high ambient weather protective enclosure
    • UL 2200 package
    • CSA Certification
    • Narrow, wide or skid base
    • EEC Declaration of Conformity
    • EU Certificate of Conformance (CE)
    • Single or dual wall sub-base fuel tanks
    • Single or dual wall integral fuel tanks
    • Automatic transfer switches (ATS)
    • Integral & sub-base UL listed dual wall fuel tanks
    • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Extended Service Coverage
    • 3, 4, 5 and 10 Years
  • Enclosures
    • High ambient sound attenuated enclosures
    • Sound attenuated enclosures
  • Exhaust System
    • Industrial silencer
    • 10 dBA Attenuation silencer
    • 6 and 8 inch elbow kit
    • Flexible exhaust fittings
    • 6 and 8 inch flange GP
    • Manifold and turbocharger guards
    • End in/end out mufflers - 10, 25 and 35 dBA attenuation
    • Engine mounted muffler
  • Fuel System
    • Dual wall 8 hour fuel tank
    • Single wall 8 hour fuel tank with spill containment
    • Low fuel level shutdown
    • Low and high fuel level alarms
    • Manual fuel transfer pump
    • Dual wall fuel tank base
    • Fuel transfer system controls
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base
  • Special Test / Reports
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • 5 Amp single Battery charger
    • Jacket water heater
    • Battery disconnect switch

Take The Virtual Product Tour To Explore The Features And Benefits of the DE660 GC (50 Hz) Generator Set

See how DE660 GC (50 Hz) compares against frequently compared products

DE660 GC (50 Hz) Diesel Generator Sets

Engine Model
C15 In-line 6, 4-cycle diesel
Voltage
380 to 415 Volts
Maximum Rating
660 kVA
Selected Model

C1.1 (60 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4, 4-cycle diesel
Voltage
110 to 480 Volts
Maximum Rating
8.8 ekW
View Full Specs

C1.1 (50 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4 4-cycle diesel
Voltage
110 to 415 Volts
Maximum Rating
9.5 kVA
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »