D500 GC (60 Hz) Generator Set

Diesel Generator Sets
Diesel Generator Sets (172)

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Generator Set Specifications

Minimum Rating
500 ekW
Maximum Rating
500 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
480 to 600 Volts
Frequency
60 Hz
Speed
1800 RPM
Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C15 In-line 6, 4-cycle diesel
Bore
5.4in
Stroke
6.8in
Displacement
928in³
Compression Ratio
16.1:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
MEUI
Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum
189.6in
Width - Maximum
64.2in
Height - Maximum
101.7in
Height - Minimum
2034in
Dry Weight - Genset (minimum)
8280.6lb
Dry Weight - Genset (maximum)
10346.3lb

Standard/Optional Features

Standard Equipment:

  • Air Inlet System
    • Air cleaner - Non canister, disposable
    • Turbocharger
    • Aftercooler core
  • Control Panel
    • GCCP 1.2
  • Cooling System
    • Blower fan and fan drive with guards
    • Jacket water pump, gear driven, centrifugal
    • Radiator sight gauge
    • Coolant drain valve
    • Thermostats and housing
    • Radiator, package mounted
  • Exhaust System
    • Exhaust manifold - dry
  • Fuel System
    • Engine fuel transfer pump
    • Primary fuel filter w/integral water separator and secondary filter, spin on
    • Integral tank base, 24 hours, UL142
    • Fuel cooler
    • Fuel priming pump
  • Generator Set
    • All protective devices and control functions simulated and checked
    • Factory tested to design specifications at full load conditions
    • Complete system designed & built at ISO 9001:2000 certified facilities
  • Generators And Generator Attachments
    • Easy access to AVR and terminals
    • Standard winding protection for non-harsh environments with relative humidity ? 95%
    • IP23 Protection
    • 6 Leads
    • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
    • Terminal box, IP22 RHS facing, bottom cable entry
    • Voltage regulator (single phase sensing)
    • Insulation system, Class H
  • Governing System
    • Cat electronic governor (ADEM A4)
  • Lube System
    • Shallow oil pan
    • Oil filter, spin on
    • Oil drain with valve
    • Lubricating oil, CK-4 (10W-30)
    • Oil cooler
    • Oil filler and dipstick
    • Fumes disposal to front of radiator
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Protection
    • Safety shutoff - High water temperature
    • Safety shutoff - Overspeed
    • Safety shutoff - Low oil pressure
  • Starting/charging System
    • 24V, 45 Amp Charging alternator
    • 24-volt electric starting motor
  • General
    • Lifting eyes
    • Vibration damper
    • Parts book

Optional Equipment:

  • Air Inlet System
    • Air cleaner (Non canister disposable)
  • Bases, Mounting & Fuel Tanks
    • Audio & visual fuel alarm (@90% fuel level)
    • Wide Base - Skid
    • 5 Gallon Spill Containment
    • Fuel tank pill pipe & lockable cap
    • Overfill prevention valve
    • Integral tank base, 24 hours, UL142
  • Exhaust
    • Industrial, residential, critical mufflers
  • Circuit Breaker
    • Auxiliary contacts
    • 600A LSI
    • 600A LS/I
    • 1200A LSI
    • 1200A LS/I
    • 400A LSI
    • 800A LSI
    • 800A LS/I
    • 400A LS/I
  • Control System
    • Twist release, Red button emergency stop
    • Ground fault relay
    • 20A GFCI (Ground Fault Circuit Interrupter)
    • Volt free contacts
    • Product link remote monitoring hardware
    • Audible alarm Gp
    • 16 -light NFPA 99/110 Annunciator
    • 100A Load center
  • Enclosures
    • E-Stop
    • AC & DC Source lights
    • Sound attenuated Level 2 enclosure (White)
  • Exhaust System
    • Manifold and turbocharger guards
    • 8" Muffler - 25 dBA attenuation
    • Flexible exhaust connection
  • Generator
    • Anti-condensation heater
    • Oversize and premium generators
    • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Permanent magnet excitation (PMG) generator
    • Space heater
  • Starting System
    • Jacket water heater
    • Battery charger (UL Certified)
    • Oversize battery set, 1400 CCA, 200 amp/hr
    • Standard battery set: 1000 CCA, 90 amp/hr.
  • Power Termination
    • Circuit breakers, UL listed
    • Circuit breakers, IEC compliant
  • General
    • CSA Certification
    • Extended Service Coverage
    • Generator test report
    • UL2200 Certification
    • CSA Certification
    • UL 2200 package
  • Lube System
    • Manual sump pump
  • Mounting System
    • Narrow skid base - replaces standard fuel tank base

Take The Virtual Product Tour To Explore The Features And Benefits of the D500 GC (60 Hz) Generator Set

See how D500 GC (60 Hz) compares against frequently compared products

D500 GC (60 Hz) Diesel Generator Sets

Engine Model
Cat® C15 In-line 6, 4-cycle diesel
Voltage
480 to 600 Volts
Maximum Rating
500 ekW
Selected Model

C1.1 (50 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4 4-cycle diesel
Voltage
110 to 415 Volts
Maximum Rating
9.5 kVA
View Full Specs

C1.1 (60 Hz) Diesel Generator Sets

Engine Model
C1.1, In-line 4, 4-cycle diesel
Voltage
110 to 480 Volts
Maximum Rating
8.8 ekW
View Full Specs

Compare with other Cat Models

Compare Now

Media Gallery

Check out our current offers

View Specials
Translate »