C18 Generator Set
Diesel Generator Sets
Diesel Generator Sets (172)
- 3516C Generator Set
- 3516E High Voltage Generator Set
- 3516B (50 Hz) with Upgradeable Package
- C32 Generator Set with Upgradeable Packaging
- C280-16 Generator Set (Medium Speed)
- C280-12 Generator Set (Medium Speed)
- 3616 Generator Set (Medium Speed)
- 3616 Generator Set (Medium Speed)
- 3612 Generator Set (Medium Speed)
- 3612 Generator Set (Medium Speed)
- 3608 Generator Set (Medium Speed)
- C280-8 Generator Set (Medium Speed)
- 3606 Generator Set (Medium Speed)
- 3608 Generator Set (Medium Speed)
- C280-6 Generator Set (Medium Speed)
- C175-20
- 3606 Generator Set (Medium Speed)
- C175-20
- C175-16 Tier 4 Final
- C175-16 Generator Set
- C175-16 Generator Set
- 3516E Low Voltage Generator Set
- 3516E Generator Set
- 3516E Low Voltage Generator Set
- 3516E Generator Set
- 3516E Low Voltage Generator Set
- 3516C Tier 4 Final
- 3516C Generator Set
- 3516C Generator Set
- 3516C (50 Hz) with Upgradeable Package
- 3516B (60 Hz) with Upgradeable Package
- 3516B Generator Set
- 3516B Generator Set
- 3516B (50 Hz) Generator Set
- 3516B Generator Set
- 3516B Generator Set
- 3516B Generator Set
- 3516 Diesel Generator Set
- 3516B (50 Hz) India Market Only
- 3516B Generator Set
- 3516 Diesel Generator Set
- 3516 Diesel Generator Set
- 3512C Generator Set
- 3516 Diesel Generator Set
- 3512B Diesel Generator Set
- 3512C Generator Set
- 3512B Diesel Generator Set
- 3512B Diesel Generator Set
- 3512B (50 Hz) Generator Set
- 3512B Diesel Generator Set
- 3512B (50 Hz) India Market Only
- 3512B (50 Hz) Generator Set
- 3512 Generator Set
- 3512 with Upgradeable Package
- 3512 Generator Set
- 3512 Generator Set
- DE1500 GC
- C32 (60 Hz)
- D1250 GC
- DE1250S GC
- DE1400 GC
- C32 Generator Set
- DE1250 GC (50 Hz)
- DE1000S GC
- D1000 GC
- DE1100 GC
- C32 (50 Hz) India Market Only
- DE800S GC
- 3412C Generator Set
- 3412C Generator Set
- C27 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- DE600S GC Generator Set
- D600 GC (60 Hz) Generator Set
- C18 Generator Set
- C18 Generator Set
- DE715 GC Generator Set
- C18 (50 Hz) India Market Only
- C18 Generator Set
- D550 GC (60 Hz) Generator Set
- DE550S GC (60 Hz) Generator Set
- DE605 GC (50 Hz) Generator Set
- DE660 GC (50 Hz) Generator Set
- D500 GC (60 Hz) Generator Set
- C15 Generator Set
- C15 Generator Set
- DE500S GC (60 Hz) Generator Set
- D450 GC (60 Hz) Generator Set
- C15 Generator Set
- C15 (50 Hz) China Non Road
- DE450S GC (60 Hz) Generator Set
- DE550 GC (50 Hz) Generator Set
- C15 (50 Hz) India Market Only
- D400 GC (60 Hz) Generator Set
- C13 Generator Set
- C13 Generator Set
- C13 (50 Hz) China Non Road
- DE500 GC (50 Hz) Generator Set
- C13 (50 Hz) India Market Only
- DE450 GC (50 Hz) Generator Set
- C13 Generator Set
- DE400 GC Generator Set
- D350 GC (60 Hz) Generator Set
- DE400S GC Generator Set
- C9 Generator Set
- C9 Generator Set
- D300 GC (60 Hz) Generator Set
- C9 Generator Set
- DE350S GC Generator Set
- D250 GC (60 Hz) Generator Set
- C7.1 Generator Set
- C7.1 ACERT
- D200 GC Generator Set
- DE220 GC (50 Hz) Generator Set
- C7.1 ACERT
- DE200 GC Generator Set (60 Hz)
- D175 GC Generator Set
- DE218AE0 (60 Hz) Generator Set
- DE218AE0 (50 Hz) Generator Set
- DE165 GC Generator Set (60 Hz)
- DE200 GC Generator Set (50 Hz)
- DE169AE0 (60 Hz) Generator Set
- D150 GC Generator Set
- DE150 GC Generator Set (60 Hz)
- DE165 GC Generator Set (50 Hz)
- DE169AE0 (50 Hz) Generator Set
- D125 GC Generator Set
- DE150 GC Generator Set (50 Hz)
- C4.4 Generator Set
- C4.4 Generator Set
- C4.4 Generator Set
- DE110 GC Generator Set (60 Hz)
- DE125AE0 (60 Hz) Generator Set
- DE125AE0 (50 Hz) Generator Set
- DE110 GC Generator Set (50 Hz)
- D100 GC Generator Set
- DE88 GC Generator Set (60 Hz)
- DE100AE0 (60 Hz) Generator Set
- D80 GC Generator Set
- DE100AE0 (50 Hz) Generator Set
- DE88 GC Generator Set (50 Hz)
- C3.3 Generator Set
- D60 GC Generator Set
- C4.4 Generator Set
- DE65 GC Generator Set (60 Hz)
- DE75AE0 (60 Hz) Generator Set
- C3.3 Generator Set
- DE65 GC Generator Set (50 Hz)
- DE75AE0 (50 Hz) Generator Set
- DE55 GC Generator Set (60 Hz)
- D50 GC Generator Set
- DE56AE0 (60 Hz) Generator Set
- DE50 GC Generator Set (60 Hz)
- DE55 GC Generator Set (50 Hz)
- D40 GC Generator Set
- DE50 GC Generator Set (50 Hz)
- DE56AE0 (50 Hz) Generator Set
- DE33 GC Generator Set (60 Hz)
- DE33 GC Generator Set (50 Hz)
- C2.2 | D30 Generator Set
- C2.2 | D25 Generator Set
- C2.2 | D20 Generator Set
- C2.2 Generator Set
- C2.2 Generator Set
- C1.5 Generator Set
- C1.5 Generator Set
- C1.1 Generator Set
- C1.1 Generator Set
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
- Cat Generator Set Package
- Cat Diesel Engine
- A-Frame Alternator
- GCCP1.3 Control Panel
- Cooling System
- Certifications
- One Safe Source
- Worldwide Product Support
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP1.3 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP1.3 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Engine Specifications
- Aspiration
- Air to Air Aftercooled
- Fuel System
- Electronic unit injection
- Engine Model
- C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
- Bore
- 145 mm (5.71 in)
- Displacement
- 18.13 L (1106.36 in3)
- Stroke
- 183 mm (7.2 in)
- Compression Ratio
- 14.5:1
- Governor Type
- Ademâ„¢A4
- Aspiration
- Air to Air Aftercooled
- Fuel System
- Electronic unit injection
- Fuel System
- Electronic unit injection
- Displacement
- 1106.36in³
- Bore
- 5.71in
- Stroke - HD
- Stroke
- 7.2in
- Bore
- 5.71in
- Stroke
- 7.2in
Generator Set Specifications
- Minimum Rating
- 550 kVA
- Maximum Rating
- 715 kVA
- Voltage
- 380 to 415 Volts
- Frequency
- 50 Hz
- Speed
- 1500 rpm
- Emissions/Fuel Strategy
- Low Fuel, China Nonroad III Emis Stds
- Duty Cycle
- Standby, Prime
Generator Set Dimensions
- Height - Maximum
- 75in
- Length - Maximum
- 162.4in
- Width - Maximum
- 78.3in
Standard/Optional Features
Standard Equipment:
-
- Air Inlet System
-
- Turbocharger
- Light duty air cleaner
- Aftercooler core
-
- Air Inlet
-
- Air cleaner
-
- Control System
-
- GCCP 1.2
-
- Exhaust
-
- Exhaust flange outlet
-
- Cooling
-
- Coolant drain line with valve
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
- Radiator and cooling fan with guard
-
- Exhaust System
-
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
-
- Fuel
-
- Secondary fuel filters
- Fuel priming pump
- Primary fuel filter with integral water separator
-
- Fuel System
-
- Standard 8 hour open set fuel tank
-
- Generator
-
- IP23 Protection
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
- Matched to the performance and output characteristics of Cat engines
-
- Generator And Attachments
-
- Segregated low voltage (AC/DC) wiring panel
- Integrated voltage regulator (IVR)
- A Frame generator - IP21 protection
- Integrated voltage regulator (IVR)
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Power center, IP22
- Matched to the performance and output characteristics of Cat engines
-
- Power Termination
-
- Busbar
-
- Governing System
-
- Cat electronic governor (ADEM A4)
-
- Control Panel
-
- GCCP Genset Controller
-
- Lube System
-
- Lubricating oil
- Oil drain valves
-
- Mounting
-
- Rubber vibration isolators
-
- Mounting System
-
- Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
-
- Starting/charging
-
- 24 Volt battery with rack and cables
-
- General
-
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment:
-
- Exhaust
-
- Industrial, residential, critical mufflers
-
- Air Inlet System
-
- Dual element air cleaner
- Single element air cleaner
-
- Circuit Breakers
-
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
- 4 Pole (IEC-100% rated) Circuit breakers - Motorised
- Circuit breaker (IEC) Auxiliary contacts
- Padlockable circuit breaker device
- 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
- 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
- Power terminal strip
- Shunt trip for IEC breaker
-
- Generator
-
- Anti-condensation heater
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Oversize and premium generators
-
- Power Termination
-
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
-
- Control Panels
-
- Local & remote annunciator modules
- Load share module
- Remote monitoring software
- EMCP (4.2) (4.3) (4.4)
- Digital I/O module
-
- Control System
-
- Oil temperature displays
- GCCP 1.5
- Volt free contact
- Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
- Local alarm modules
- Remote annunciator module
- Local alarm horn
-
- Cooling System
-
- Low coolant temperature alarm
- Radiator duct flange
-
- Starting/charging
-
- Oversize batteries
- Jacket water heater
- Battery chargers
- Heavy duty starting system
- Charging alternator
-
- Enclosures
-
- Sound attenuated enclosures
-
- Exhaust System
-
- Manifold and turbocharger guards
- Engine mounted muffler
- 8 and 10 inch elbow kits
- 8 and 10 inch GP flanges
- 10, 25 and 35 end in / end outmufflers
-
- Fuel System
-
- Integral - Dual wall fuel tank base
- Manual fuel transfer pump
- Fuel transfer system
-
- Generator And Attachments
-
- LC frame generator
- Permanent magnet excitation (PMG)
- LC frame oversize generators
- Space heaters
- A Frame oversize generator
- A Frame CIP generator
- Ingress protection
- LC frame CIP generator
-
- General
-
- Single or dual wall integral fuel tanks
- UL 2200 package
- Enclosures: Sound attenuated, weather protective
- EU Certificate of Conformance (CE)
- Integral & sub-base UL listed dual wall fuel tanks
- Narrow, wide or skid base
- The following options are based on regional and product configuration:
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EEC Declaration of Conformity
- CSA Certification
- Sound attenuated, weather protective or high ambient weather protective enclosure
- Automatic transfer switches (ATS)
- Single or dual wall sub-base fuel tanks
-
- Lube System
-
- Manual sump pump
-
- Starting And Charging
-
- Jacket water heaters
- 5 Amp Battery charger
- Battery disconnect switch