3512 with Upgradeable Package
Diesel Generator Sets
Diesel Generator Sets (172)
- 3516C Generator Set
- 3516E High Voltage Generator Set
- C32 Generator Set with Upgradeable Packaging
- 3516B (50 Hz) with Upgradeable Package
- C280-16 Generator Set (Medium Speed)
- 3616 Generator Set (Medium Speed)
- C280-12 Generator Set (Medium Speed)
- 3616 Generator Set (Medium Speed)
- 3612 Generator Set (Medium Speed)
- C280-8 Generator Set (Medium Speed)
- 3612 Generator Set (Medium Speed)
- 3608 Generator Set (Medium Speed)
- 3608 Generator Set (Medium Speed)
- C280-6 Generator Set (Medium Speed)
- 3606 Generator Set (Medium Speed)
- 3606 Generator Set (Medium Speed)
- C175-20
- C175-20
- C175-16 Tier 4 Final
- C175-16 Generator Set
- C175-16 Generator Set
- 3516E Low Voltage Generator Set
- 3516E Low Voltage Generator Set
- 3516E Generator Set
- 3516E Generator Set
- 3516E Low Voltage Generator Set
- 3516C Tier 4 Final
- 3516C Generator Set
- 3516C Generator Set
- 3516C (50 Hz) with Upgradeable Package
- 3516B (60 Hz) with Upgradeable Package
- 3516B Generator Set
- 3516B Generator Set
- 3516B (50 Hz) Generator Set
- 3516B Generator Set
- 3516B Generator Set
- 3516B Generator Set
- 3516B (50 Hz) India Market Only
- 3516B Generator Set
- 3516 Diesel Generator Set
- 3516 Diesel Generator Set
- 3516 Diesel Generator Set
- 3516 Diesel Generator Set
- 3512B Diesel Generator Set
- 3512C Generator Set
- 3512C Generator Set
- 3512B Diesel Generator Set
- 3512B Diesel Generator Set
- 3512B (50 Hz) Generator Set
- 3512B Diesel Generator Set
- 3512B (50 Hz) India Market Only
- 3512B (50 Hz) Generator Set
- 3512 Generator Set
- 3512 Generator Set
- 3512 with Upgradeable Package
- 3512 Generator Set
- DE1500 GC
- C32 (60 Hz)
- D1250 GC
- DE1250S GC
- DE1400 GC
- C32 Generator Set
- DE1100 GC
- DE1250 GC (50 Hz)
- C32 (50 Hz) India Market Only
- DE1000S GC
- D1000 GC
- 3412C Generator Set
- C27 Generator Set
- DE800S GC
- C18 Generator Set
- 3412C Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- DE600S GC Generator Set
- C18 Generator Set
- D600 GC (60 Hz) Generator Set
- C18 Generator Set
- DE715 GC Generator Set
- C18 Generator Set
- D550 GC (60 Hz) Generator Set
- C18 (50 Hz) India Market Only
- DE550S GC (60 Hz) Generator Set
- DE605 GC (50 Hz) Generator Set
- DE660 GC (50 Hz) Generator Set
- C15 Generator Set
- C15 Generator Set
- DE500S GC (60 Hz) Generator Set
- D500 GC (60 Hz) Generator Set
- D450 GC (60 Hz) Generator Set
- C15 (50 Hz) China Non Road
- DE450S GC (60 Hz) Generator Set
- C15 Generator Set
- DE550 GC (50 Hz) Generator Set
- C15 (50 Hz) India Market Only
- C13 Generator Set
- C13 Generator Set
- DE500 GC (50 Hz) Generator Set
- D400 GC (60 Hz) Generator Set
- C13 (50 Hz) China Non Road
- DE450 GC (50 Hz) Generator Set
- C13 Generator Set
- C13 (50 Hz) India Market Only
- D350 GC (60 Hz) Generator Set
- DE400S GC Generator Set
- DE400 GC Generator Set
- C9 Generator Set
- D300 GC (60 Hz) Generator Set
- C9 Generator Set
- C9 Generator Set
- D250 GC (60 Hz) Generator Set
- C7.1 Generator Set
- DE350S GC Generator Set
- C7.1 ACERT
- D200 GC Generator Set
- DE220 GC (50 Hz) Generator Set
- C7.1 ACERT
- DE200 GC Generator Set (60 Hz)
- D175 GC Generator Set
- DE218AE0 (60 Hz) Generator Set
- DE165 GC Generator Set (60 Hz)
- DE200 GC Generator Set (50 Hz)
- DE169AE0 (60 Hz) Generator Set
- D150 GC Generator Set
- DE218AE0 (50 Hz) Generator Set
- DE150 GC Generator Set (60 Hz)
- DE165 GC Generator Set (50 Hz)
- DE169AE0 (50 Hz) Generator Set
- DE150 GC Generator Set (50 Hz)
- D125 GC Generator Set
- C4.4 Generator Set
- C4.4 Generator Set
- DE110 GC Generator Set (60 Hz)
- DE125AE0 (60 Hz) Generator Set
- C4.4 Generator Set
- DE125AE0 (50 Hz) Generator Set
- D100 GC Generator Set
- DE110 GC Generator Set (50 Hz)
- DE88 GC Generator Set (60 Hz)
- DE100AE0 (60 Hz) Generator Set
- DE100AE0 (50 Hz) Generator Set
- D80 GC Generator Set
- DE88 GC Generator Set (50 Hz)
- D60 GC Generator Set
- C4.4 Generator Set
- DE65 GC Generator Set (60 Hz)
- C3.3 Generator Set
- DE75AE0 (60 Hz) Generator Set
- C3.3 Generator Set
- DE65 GC Generator Set (50 Hz)
- DE75AE0 (50 Hz) Generator Set
- DE55 GC Generator Set (60 Hz)
- DE56AE0 (60 Hz) Generator Set
- D50 GC Generator Set
- DE50 GC Generator Set (60 Hz)
- DE55 GC Generator Set (50 Hz)
- D40 GC Generator Set
- DE50 GC Generator Set (50 Hz)
- DE56AE0 (50 Hz) Generator Set
- DE33 GC Generator Set (60 Hz)
- DE33 GC Generator Set (50 Hz)
- C2.2 | D25 Generator Set
- C2.2 | D30 Generator Set
- C2.2 | D20 Generator Set
- C2.2 Generator Set
- C1.5 Generator Set
- C2.2 Generator Set
- C1.5 Generator Set
- C1.1 Generator Set
- C1.1 Generator Set
Overview
The 3512A generator set withUpgradeable Packaging has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.
- Cat Generator Set Package
- Cat Diesel Engine
- SR5 Alternator
- EMCP 4 Control Panel
- Cooling System
- One Safe Source
- Worldwide Product Support
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
EMCP 4 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
- Minimum Rating
- 890 ekW
- Maximum Rating
- 1250 ekW
- Emissions/Fuel Strategy
- Low Fuel Consumption
- Voltage
- 380 to 480 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby, Mission Critical, Prime, Continuous
- Standby Rating
- 1250/1100 ekW
- Prime Power Rating
- 1135/1000 ekW
Engine Specifications
- Engine Model
- 3512A, V-12, 4-Stroke Water-Cooled Diesel
- Bore
- 6.69in
- Stroke
- 7.48in
- Displacement
- 3161.03in³
- Compression Ratio
- 13.5:1
- Aspiration
- TA
- Fuel System
- MUI
- Governor Type
- Woodward
Generator Set Dimensions
- Length - Maximum
- 203.5in
- Width - Maximum
- 79.3in
- Height - Maximum
- 92in
- Dry Weight - Genset (minimum)
- 22099lb
- Dry Weight - Genset (maximum)
- 22540lb
Standard/Optional Features
Standard Equipment:
-
- Air Inlet System
-
- Air cleaner; single element canister type with service indicator
-
- Control Panel
-
- Auto/start/stop control
- True RMS AC metering, 3-phase, +/-2% accuracy
- kVAr-hr (total)
- EMCP 4.2B
- kVAr (per phase, average & percent)
- Customer data link (Modbus RTU)
- KVAR/PF modes, RFI suppression, min/max exciter
- Overcurrent (50/51)
- IVR includes reactive droop capability, 3-phase voltage sensing
- Generator phase sequence
- 6 programmable digital inputs
- Engine cool-down timer
- Limiter and exciter diode monitor
- Over/under voltage (27/59)
- Low coolant temperature
- Generator set packages include Caterpillar's voltage regulator (IVR)
- Accessory module data link
- Low oil pressure
- Over/under frequency (81 o/u)
- Generator mounted - rear facing
- Reverse reactive power (kVAr) (32RV)
- Emergency stop
- Lamp test
- Overspeed
- kVA (per phase, average & percent)
- Operating hours
- DC volts
- Low coolant level
- Programmable protective relaying functions:
- Frequency (Hz)
- Amps (per phase & average)
- Environmental sealed front face
- Failure to start (overcrank)
- Power factor (per phase & average)
- Controls:
- kW (per phase, average & percent)
- Oil pressure (psi, kPa or bar)
- 24 Volt DC operation
- 4 programmable relay outputs (Form A)
- Emergency stop pushbutton
- 2 Programmable relay outputs (Form C)
- RPM
- Digital indication for:
- Engine cycle crank
- Speed adjust
- Coolant temperature
- 2 Programmable digital outputs
- Text alarm/event descriptions
- Serial annunciator module data link
- Communications:
- kW-hr (total)
- Volts (L-L & L-N)
- Alarm acknowledge
- Warning/shutdown with common LED indication of shutdowns for:
- Reverse power (kW) (32)
- High coolant temperature
-
- Cooling System
-
- Coolant level sensors (Not included with packages without radiator)
- Coolant drain line with valve
- Fan and belt guards
- JWAC
- Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
- Caterpillar extended life coolant. (Not included with packages without radiator, installed SF44CTS, shipped loose radiators or heat exchangers)
-
- Exhaust
-
- Dry exhaust manifold
- Flanged faced outlet(s)
-
- Fuel System
-
- Fuel priming pump
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Flexible fuel lines - shipped loose
-
- Generators And Attachments
-
- Internal excitation (IE) or Permanent magnet excitation (PMG)
- Winding temperature detectors
- 6 Lead
- LV
- 60 Hz models: NEMA standard hole pattern
- Busbar connections, top center mounted, top cable entry
- 3 Phase brushless, Salient pole
- Random wound
- NEMA Class H insulation
- Class H temperature rise at 40C ambient (125C prime / 150C standby)
- KVAR/PF modes
- Exciter diode monitor
- Caterpillar's digital voltage regulator (CDVR) includes:
- RFI suppression
- Reactive droop capability
- Min / max exciter limiter
- Note: 1800 Frames are form wound, permanent magnet excitation (PMG), with winding temp detectors
- Generator set packages include: Regulator (CDVR)
- 3 Phase voltage sensing
-
- Governing System
-
- Woodward 2301A isochronous governor
-
- Lube System
-
- Fumes disposal
- Lubricating oil
- Gear type lube oil pump
- Oil filter, filler and dipstick
- Integral lube Oil cooler
- Oil drain lines and valve
-
- Mounting System
-
- Rails - engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
-
- Starting / Charging System
-
- 24-Volt electric starting motor
- Battery and battery rack w/cables
- 50 Amp Charging alternator
- Battery disconnect switch
-
- General
-
- Flywheel and Flywheel housing-SAE No. 00
- SAE standard rotation
- RH service
- Paint - Caterpillar yellow with high gloss black rails & radiator
Optional Equipment:
-
- Air Inlet System
-
- Single stage air cleaners
- Dual element air filters
-
- Circuit Breakers
-
- 2000, 2500, 3200 and 4000 Amp, 4 pole, IEC rated Circuit breakers
-
- Control Panels
-
- Remote custom annunicator
- CAN2 network equipment
- Modbus monitoring of packages
- EMCP 4.3, EMCP 4.4
- Local discrete I/O package
- Vandle proof panel door
- Cat connect
- Load share module options
- First local annunciator
-
- Cooling System
-
- Coolant
- Water level gauge
- Optional radiator arrangements
-
- Exhaust System
-
- Exhaust flexible fittings
- Industrial grade (15 db) mufflers
- Exhaust elbows
- Exhaust Y Adapters
-
- Generators And Attachments
-
- Space heater control
- Space heater
- Generator conversion
- Space heater
- Space heater control
- 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, random wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
- 1500 RPM, 380/400/415volts @ 50 Hz, 3 phase, Form wound, Permanent magnet excitation (PMG), No. of leads = 6, pitch= 0.6667
-
- Lube System
-
- Oil level regulator
- Lube oil
- Primary fuel systems
- Prelube sump pump
- Oil level regulator
-
- Special Tests / Reports
-
- Gensets vibration analysis
- PGS Test report @ 1.0 power factor
- PKG factory test report
- Standard genset TVA report
- Standard engine test charge
- Fuel consumption test
- Generator test report
- Standard engine test charge
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
- Torsional vibration analysis
- Generator test report
-
- Crankcase System
-
- Protection systems
- Ventilation system
- Protection systems
- Ventilation system
-
- Batteries And Battery Housing
-
- Battery chargers - 10, 20 and 35 amp
- 24 Volt battery set - Dry
- Battery chargers - 10, 20 and 35 amp
- 24 Volt battery set - Dry
-
- Mounting System
-
- Spring type vibration isolators
- Puck style low efficiency lsolators
- IBC vibration isolators
- Spring type vibration isolators
-
- Instrumentation
-
- Pyrometer and thermocouples
-
- Protection System
-
- Explosion relief valves
-
- Starting / Charging Systems
-
- Oversize battery set
- Jacket water heater
- Electric starting motors
- Jacket water heaters
- 24 Volt dual electric starting motor
- Starter cover
-
- General
-
- Barring devices
-
- Power Connection System
-
- Breaker power connections
- EMCP voltage and current sensing groups
- Center post busbars
-
- Circuit Breaker - Lv Packages
-
- Electronically operated circuit breakers
- Right hand power connections