ATC Contactor-Based Automatic Transfer Switch
ATS ATC Breaker / Contactor
ATS ATC Breaker / Contactor (8)
- ATC-800 CONTROLLER
- ATC-300+ CONTROLLER
- ATC Contactor Based Bypass Isolation Automatic Transfer Switch
- ATC Power Breaker Bypass Isolation Open/Closed Transition Automatic Transfer Switch
- ATC Service Entrance Rated MCCB & Power Breaker Based ATS
- ATC Molded Case Circuit Breaker & Molded Case Switch Automatic Transfer Switch
- ATC Contactor-Based Automatic Transfer Switch
- ATC Power Breaker & Case Switch Automatic Transfer Switch
Overview
Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open and delayed transition contactor-based Automatic Transfer Switch (ATS) provides fully functioning transfer in Applications where a momentary loss of power is acceptable during transfer and retransfers between normal and emergency power supply.
The closed transition contactor-based ATS is designed to Meet application requirements where emergency back up power is required with no momentary loss of power by connecting both sources before the transfer occurs. Closed transition also permits periodic testing of the emergency power source without interrupting power to the loads.
Product Features
- ATC-100, ATC-300+ or ATC-800 microprocessor-based controller
- Voltage and frequency sensing
- High withstand and closing ratings
- Multiple field programmable set points
- Status Display including switch position indication
- Source availability indication
Product Features
- ATC-100, ATC-300+ or ATC-800 microprocessor-based controller
- Voltage and frequency sensing
- High withstand and closing ratings
- Multiple field programmable set points
- Status Display including switch position indication
- Source availability indication
- Source 1 and 2 auxiliary contacts
- True RMS voltage and frequency sensing
- Programmable plant exerciser
- System test pushbutton
- Mimic diagram
- Double-throw, mechanically interlocked transfer mechanism
- Switch position indication
- Status display
- Double-throw UL 1008 3-position contactors
Technical Summary
- Rating Range
- 40-1600A
- Transfer Type
- Open / Closed Transition
- Switch Type
- Contactor Based
- Rating Range
- 40-3000A
- Transfer Type
- Open / Closed Transition
- Switch Type
- Contactor Based
Ratings
- Control Power
-
Wall Mount 40-600A 2 or 3 Pole
Floor Standing 600A 4 Pole & 800-1200A 2, 3, or 4 Pole - Two-Position Contactors
- Two-position contactors 40-400A
- Three-Position Contactors
- Three-position contactors 40-1200A
- System Voltage Application
- Up to 600 Vac, 50/60 Hz
- Applicable Testing
- UL 1008 listed, CSA C22.2 No. 178 certified, IBC 2006, CBC 2007 and OSHPD
Standard/Optional Features
Standard Equipment:
-
- Contact Composition
-
- Caterpillar utilizes silver composition contacts designed to meet the stringent requirements of UL 1008. All contactors are designed so that the contacts can be visually inspected without major disassembly and are protected by arcing contacts.
-
- Controls And Wiring
-
- All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
-
- Enclosure
-
- Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.
Optional Equipment:
-
- Available Options
-
- 2- or 4-position test switch
- Controller availability: ATC-100, ATC-300+,and ATC-800
- Delayed transition or closed transition
- Multi-meter options available
- Surge suppression
- Space heaters
- Field selectable, multi ratio, control voltage transformer 50/60 Hz
- Selectable automatic or non-automatic operation
- Remote communications
- Load shed from emergency
-
- Optional Delayed Transition Includes:
-
- Pre-transfer signal with 1 N.O. and 1 N.C. contacts
- Time delay neutral