D550 GC (60 Hz) Generator Set
Diesel Generator Sets
Diesel Generator Sets (172)
- 3516C Generator Set
- 3516E High Voltage Generator Set
- 3516B (50 Hz) with Upgradeable Package
- C32 Generator Set with Upgradeable Packaging
- C280-16 Generator Set (Medium Speed)
- C280-12 Generator Set (Medium Speed)
- 3616 Generator Set (Medium Speed)
- 3616 Generator Set (Medium Speed)
- 3612 Generator Set (Medium Speed)
- 3612 Generator Set (Medium Speed)
- 3608 Generator Set (Medium Speed)
- C280-8 Generator Set (Medium Speed)
- 3606 Generator Set (Medium Speed)
- 3608 Generator Set (Medium Speed)
- C280-6 Generator Set (Medium Speed)
- C175-20
- 3606 Generator Set (Medium Speed)
- C175-20
- C175-16 Tier 4 Final
- C175-16 Generator Set
- C175-16 Generator Set
- 3516E Low Voltage Generator Set
- 3516E Generator Set
- 3516E Low Voltage Generator Set
- 3516E Generator Set
- 3516E Low Voltage Generator Set
- 3516C Tier 4 Final
- 3516C Generator Set
- 3516C Generator Set
- 3516C (50 Hz) with Upgradeable Package
- 3516B (60 Hz) with Upgradeable Package
- 3516B Generator Set
- 3516B Generator Set
- 3516B (50 Hz) Generator Set
- 3516B Generator Set
- 3516B Generator Set
- 3516B Generator Set
- 3516 Diesel Generator Set
- 3516B (50 Hz) India Market Only
- 3516B Generator Set
- 3516 Diesel Generator Set
- 3516 Diesel Generator Set
- 3512C Generator Set
- 3516 Diesel Generator Set
- 3512B Diesel Generator Set
- 3512C Generator Set
- 3512B Diesel Generator Set
- 3512B Diesel Generator Set
- 3512B (50 Hz) Generator Set
- 3512B Diesel Generator Set
- 3512B (50 Hz) India Market Only
- 3512B (50 Hz) Generator Set
- 3512 Generator Set
- 3512 with Upgradeable Package
- 3512 Generator Set
- 3512 Generator Set
- DE1500 GC
- C32 (60 Hz)
- D1250 GC
- DE1250S GC
- DE1400 GC
- C32 Generator Set
- DE1250 GC (50 Hz)
- DE1000S GC
- D1000 GC
- DE1100 GC
- C32 (50 Hz) India Market Only
- DE800S GC
- 3412C Generator Set
- 3412C Generator Set
- C27 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- C18 Generator Set
- DE600S GC Generator Set
- D600 GC (60 Hz) Generator Set
- C18 Generator Set
- C18 Generator Set
- DE715 GC Generator Set
- C18 (50 Hz) India Market Only
- C18 Generator Set
- D550 GC (60 Hz) Generator Set
- DE550S GC (60 Hz) Generator Set
- DE605 GC (50 Hz) Generator Set
- DE660 GC (50 Hz) Generator Set
- D500 GC (60 Hz) Generator Set
- C15 Generator Set
- C15 Generator Set
- DE500S GC (60 Hz) Generator Set
- D450 GC (60 Hz) Generator Set
- C15 Generator Set
- C15 (50 Hz) China Non Road
- DE450S GC (60 Hz) Generator Set
- DE550 GC (50 Hz) Generator Set
- C15 (50 Hz) India Market Only
- D400 GC (60 Hz) Generator Set
- C13 Generator Set
- C13 Generator Set
- C13 (50 Hz) China Non Road
- DE500 GC (50 Hz) Generator Set
- C13 (50 Hz) India Market Only
- DE450 GC (50 Hz) Generator Set
- C13 Generator Set
- DE400 GC Generator Set
- D350 GC (60 Hz) Generator Set
- DE400S GC Generator Set
- C9 Generator Set
- C9 Generator Set
- D300 GC (60 Hz) Generator Set
- C9 Generator Set
- DE350S GC Generator Set
- D250 GC (60 Hz) Generator Set
- C7.1 Generator Set
- C7.1 ACERT
- D200 GC Generator Set
- DE220 GC (50 Hz) Generator Set
- C7.1 ACERT
- DE200 GC Generator Set (60 Hz)
- D175 GC Generator Set
- DE218AE0 (60 Hz) Generator Set
- DE218AE0 (50 Hz) Generator Set
- DE165 GC Generator Set (60 Hz)
- DE200 GC Generator Set (50 Hz)
- DE169AE0 (60 Hz) Generator Set
- D150 GC Generator Set
- DE150 GC Generator Set (60 Hz)
- DE165 GC Generator Set (50 Hz)
- DE169AE0 (50 Hz) Generator Set
- D125 GC Generator Set
- DE150 GC Generator Set (50 Hz)
- C4.4 Generator Set
- C4.4 Generator Set
- C4.4 Generator Set
- DE110 GC Generator Set (60 Hz)
- DE125AE0 (60 Hz) Generator Set
- DE125AE0 (50 Hz) Generator Set
- DE110 GC Generator Set (50 Hz)
- D100 GC Generator Set
- DE88 GC Generator Set (60 Hz)
- DE100AE0 (60 Hz) Generator Set
- D80 GC Generator Set
- DE100AE0 (50 Hz) Generator Set
- DE88 GC Generator Set (50 Hz)
- C3.3 Generator Set
- D60 GC Generator Set
- C4.4 Generator Set
- DE65 GC Generator Set (60 Hz)
- DE75AE0 (60 Hz) Generator Set
- C3.3 Generator Set
- DE65 GC Generator Set (50 Hz)
- DE75AE0 (50 Hz) Generator Set
- DE55 GC Generator Set (60 Hz)
- D50 GC Generator Set
- DE56AE0 (60 Hz) Generator Set
- DE50 GC Generator Set (60 Hz)
- DE55 GC Generator Set (50 Hz)
- D40 GC Generator Set
- DE50 GC Generator Set (50 Hz)
- DE56AE0 (50 Hz) Generator Set
- DE33 GC Generator Set (60 Hz)
- DE33 GC Generator Set (50 Hz)
- C2.2 | D30 Generator Set
- C2.2 | D25 Generator Set
- C2.2 | D20 Generator Set
- C2.2 Generator Set
- C2.2 Generator Set
- C1.5 Generator Set
- C1.5 Generator Set
- C1.1 Generator Set
- C1.1 Generator Set
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
- Cat Generator Set Package
- Cat Diesel Engine
- SR500 Alternator
- GCCP 1.2 Control Panel
- Cooling System
- Certifications
- One Safe Source
- Worldwide Product Support
Cat Generator Set Package
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR500 Alternator
M-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.2 Control Panel
GCCP 1.2 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
Cooling System
- Designed to operate in standard ambient temperatures up to104°F (40°C)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Certifications
- UL 2200 Listed
- ULC Certification Available
One Safe Source
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
Worldwide Product Support
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Generator Set Package
Cat Generator Set Package
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
Cat Diesel Engine
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR500 Alternator
M-Frame Alternator
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
GCCP 1.2 Control Panel
GCCP 1.2 Control Panel
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
Cooling System
Cooling System
- Designed to operate in standard ambient temperatures up to104°F (40°C)
- Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Certifications
- UL 2200 Listed
- ULC Certification Available
One Safe Source
One Safe Source
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
Worldwide Product Support
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Generator Set Specifications
- Minimum Rating
- 550 ekW
- Maximum Rating
- 550 ekW
- Emissions/Fuel Strategy
- EPA Stationary Emergency
- Voltage
- 480 to 600 Volts
- Frequency
- 60 Hz
- Speed
- 1800 rpm
- Duty Cycle
- Standby
Engine Specifications
- Engine Model
- Cat® C18 In-line 6, 4-cycle diesel
- Bore
- 5.7in
- Stroke
- 7.2in
- Displacement
- 1106in³
- Compression Ratio
- 14.5:1
- Aspiration
- Turbocharged Air-to-Air Aftercooled
- Fuel System
- MEUI
- Governor Type
- ADEM™A4
Generator Set Dimensions
- Length - Maximum
- 196.1in
- Width - Maximum
- 73.4in
- Height - Maximum
- 100.9in
- Height - Minimum
- 79.1in
- Dry Weight - Genset (minimum)
- 8776.6lb
- Dry Weight - Genset (maximum)
- 11464lb
Standard/Optional Features
Standard Equipment:
-
- Air Inlet System
-
- Air cleaner - Non canister, disposable
- Aftercooler core
- Turbocharger
-
- Control Panel
-
- GCCP 1.2
-
- Cooling System
-
- Jacket water pump, gear driven, centrifugal
- Radiator, package mounted
- Radiator sight gauge
- Thermostats and housing
- Blower fan and fan drive with guards
- Coolant drain valve
-
- Exhaust System
-
- Exhaust manifold - dry
-
- Fuel System
-
- Fuel priming pump
- Primary fuel filter w/integral water separator and secondary filter, spin on
- Engine fuel transfer pump
- Fuel cooler
- Integral tank base, 24 hours, UL142
-
- Generator Set
-
- Complete system designed & built at ISO 9001:2000 certified facilities
- All protective devices and control functions simulated and checked
- Factory tested to design specifications at full load conditions
-
- Generators And Generator Attachments
-
- Insulation system, Class H
- Standard winding protection for non-harsh environments with relative humidity ? 95%
- Terminal box, IP22 RHS facing, bottom cable entry
- IP23 Protection
- 6 Leads
- Voltage regulator (single phase sensing)
- Easy access to AVR and terminals
- Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
-
- Governing System
-
- Cat electronic governor (ADEM A4)
-
- Lube System
-
- Lubricating oil, CK-4 (10W-30)
- Oil cooler
- Oil drain with valve
- Shallow oil pan
- Oil filter, spin on
- Fumes disposal to front of radiator
- Oil filler and dipstick
-
- Mounting System
-
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
-
- Protection
-
- Safety shutoff - Overspeed
- Safety shutoff - Low oil pressure
- Safety shutoff - High water temperature
-
- Starting/charging System
-
- 24-volt electric starting motor
- 24V, 45 Amp Charging alternator
-
- General
-
- Lifting eyes
- Parts book
- Vibration damper
Optional Equipment:
-
- Air Inlet System
-
- Air cleaner (Non canister disposable)
-
- Bases, Mounting & Fuel Tanks
-
- Integral tank base, 24 hours, UL142
- Fuel tank pill pipe & lockable cap
- Audio & visual fuel alarm (@90% fuel level)
- 5 Gallon Spill Containment
- Overfill prevention valve
- Wide Base - Skid
-
- Circuit Breaker
-
- 400A LS/I
- 1200A LS/I
- Auxiliary contacts
- 800A LSI
- 800A LS/I
- 600A LSI
- 600A LS/I
- 400A LSI
- 1200A LSI
-
- Control System
-
- Volt free contacts
- 20A GFCI (Ground Fault Circuit Interrupter)
- 16 -light NFPA 99/110 Annunciator
- Twist release, Red button emergency stop
- Product link remote monitoring hardware
- 100A Load center
- Ground fault relay
- Audible alarm Gp
- Annunciators box
- Remote E-Stop button
- Local annunciator
- Discrete I/O module
- Volt free contact
- Earth (Ground) fault relay
-
- Enclosures
-
- Sound attenuated Level 2 enclosure (White)
- AC & DC Source lights
- E-Stop
- Sound attenuated enclosure
-
- Exhaust System
-
- Flexible exhaust connection
- Manifold and turbocharger guards
- 8" Muffler - 25 dBA attenuation
-
- Generator
-
- Space heater
- Permanent magnet excitation (PMG) generator
-
- Starting System
-
- Standard battery set: 1000 CCA, 90 amp/hr.
- Battery charger (UL Certified)
- Jacket water heater
- Oversize battery set, 1400 CCA, 200 amp/hr
-
- General
-
- CSA Certification
- Extended Service Coverage
- UL2200 Certification
- Generator test report
- Tool set
-
- Circuit Breakers
-
- Single LSI motorised circuit breaker
- Auxiliary contacts
- Neutral bar (208V)
-
- Cooling System
-
- Jacket water heater with pump
- Coolant heater
- Stone guards
-
- Base / Fuel Tank
-
- Audio & visual fuel alarm
-
- Fuel System
-
- Integral 8 hour tank base
-
- Starting And Charging
-
- Oversize battery set
- Battery disconnect switch
- 5 Amp Battery charger
- Standard battery set
-
- Certifications
-
- UL2200 Listed
- CSA 22.2
- Seismic
-
- Lube System
-
- Manual sump pump